Flow insert with circular and V-shaped plate
Flow poke for bubbler flow meterFlow insert installed

Flow metering inserts CQ4

 

Range of flow inserts for ISCO Signature bubbler flow meter. They can easily be installed in the pipes up to 300 mm in diameter, swelling the tube.

  • Rubber and integrated inflation tube
  • 4 models available for circular pipes from 150 mm to 300 mm
  • Connecting tube and elbow extension available
  • Accuracy of +/-5% for slopes less than 2.5%
  • circular and 60° V-notch shaped plate

Flow inserts with circular and V-shaped orifice

Operating principle

Measurement of very low flow rates in free-flow pipes, with choice of contraction type.
Simple to use and highly accurate.
Assemble the poles with the sleeve, connect the tubes to the pump and flow meter, set the zero point using air, then, starting from the inspection chamber, insert the sleeve into the pipe and inflate the rubber air chamber with the pump to ensure a tight seal.

 

Flow rate range table

Flow poke size Circular orifice V-shaped orifice
Diameter 150mm 1 to 40 m3/h 0,3 to 20 m3/h
Diameter 200mm 2,5 to 72 m3/h 0,3 to 36 m3/h
Diameter 250mm 4,5 to 109 m3/h 0,3 to 52 m3/h
Diameter 300mm 9 to 145 m3/h 0,3 to 72 m3/h

 

Technical Data

Materials Anodized aluminum
Accuracy +/- 5% (slope less than 2.5%)
Inflation hose length 6,1 m
Inflation pressure 0,8 up to 1 bar
Maximum permissible pressure 1.5 bar on smooth PVC pipe without rough edges
V weir plate measurement angle 60°

 

 

Flow inserts datasheet

 

REQUEST A QUOTE

Clear
GDPR logo - Ijinus
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.