Overflow detector CSCV3
Easy water samplingCapacitive Technology - Storm-overflow monitoringStorm overflow sensor CSCV3

Overflow detector CSCV3

  • Capacitive technology with air referential
  • Management and monitoring of fouling
  • Sealing : IP68
  • Dynamic analysis of thresholds
  • TOR NO/NC, MODBUS
  • Compatibility with PLC and process
  • Technology patented by IJINUS

IJINUS presents the first overflow sensor that integrates the CapAir® technology, IJINUS patent, simplifying installation and reducing maintenance considerably compared to a resistive and a traditional capacitive technology.

The CapAir® technology, capacitive measurement with air referential, enables reliable and unequaled water overflows detection in the toughest conditions. For reliable detection, the capacitive measurement is temperature compensated.

CSCV3 liquid detector description

Modbus or digital communication

The overflow detectors of the CSCV3 range can be associated with:

– A PLC allowing, for example the starting or stopping of the lifting station pumps.
– An automatic water sampler, it allows to control it for the sampling of wastewater.
– A flowmeter
– A radar water level sensor LNR06V4, or LNU06V4 ultrasonic level sensors: to modulate its measurement and data sending period.
– A Logger with contact input from the LOG03V4 range, or Modbus input from the LOG04V4 range.

Possible output options (selectable for each output):

– NO or NC mode for overflow state
– NO or NF mode for power status
– Generation of pulses proportional to the time in overflow
– Delay before activation of the output
– Delay of the output activation>
– RS485 Modbus

The different detector versions :

– 8 bare wires : CSCV3-110
– M12 8Pts Connector : CSCV3-810
– Connector to connect to ISCO water sampler : CSC-710-ISCO

Remote data monitoring options

The overflow detector CSC connected to a LNU level sensor or a LOG V4 data logger integrating a modem, sends data in 2G/4G (LTE-M or NB-IoT), to SCADA software or our remote monitoring web platform.

Overflow detector CSCV3 applications :

  • Monitoring of storm overflows
  • Surface water & Waste water monitoring
  • Sewer overflow monitoring

CSCV3 specifications

Dimensions

Dimensions liquid detector CSCV3
Wired Capacitive detectors
To be uses with LOG03V4, LOG03V4, LNU06V4, LNR06V4, PLC and pumps
Technology Capacitive technology with air referential
IJINUS Patent
Detection threshold Factory setting : 90 % on dynamic threshold for wastewater
Update time Factory setting : 30s
Adjustable by 5s step
Operating temperature -40 …80°C
Housing
Black crystalline polymer
Fixing material Inox
Sealing IP68
Power supply :- Internal battery
or
external power supply
– Bat : 3,6V 7Ah (Battery lasts 8 years min)

– 3,6…16V
Configuration
Wireless programming kit (PN : MOC0000x), via Modbus LOG V3 or sensor LNU V3
Weight CSCV3-110 790g
Cable 10m
Output 1 Modbus RS485
1 Open drain Pulse
1 Open drain NO
1 Open drain NC
Versions Bare wire 8 brins : CSCV3-110
With connector M12 8Pts : CSCV3-810
With connector for ISCO sampler : CSC-710-ISCO

 